BLRDC - L-4638-A OXYGEN

Product Identification

Product ID:L-4638-A OXYGEN
MSDS Date:09/01/1985
FSC:6505
NIIN:00-132-5225
MSDS Number: BLRDC

Responsible Party
UNION CARBIDE CORP/LINDE DIV
39 OLD RIDGEBURY ROAD
DANBURY, CT 06817-0001

Emergency Phone: (304) 744-3487

Info Phone: (304) 744-3487

Cage: 61637

Contractor
UNION CARBIDE CORP
DANBURY, CT 06817-0001 US

Telephone: 800-822-4357/732-563-5522 (MSDS)

Cage: 61637

Ingredients

OXYGEN (GAS)

CAS: 7782-44-7

RTECS: RS2060000

Fraction By Weight: 100%

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: NASAL
STUFFINESS/COUGH/SORE THROAT/CHEST PAIN/BREATHING DIFFICULTY/LUNG
DAMAGE/CNS EFFECTS RESULTING IN DIZZINESS/POOR
COORDINATION/TINGLING SENSATION/VISUAL & HEARING
DISTURBANCES/MUSCULA R
TWITCHING/UNCONSCIOUSNESS/CONVULSIONS/PROLONGATION OF ADAPTATION TO
DARKNESS/REDUCED PERIPHERAL VISION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: ALVEOLAR COLLAPSE FOLLOWING OXYGEN
ABSORPTION, EARDRUM RETRACTION, OBSTRUCTION OF PARANASAL SINUSES
PRODUCING VACUUM-TYPE HEADACHE. NEWBORN PREMATURE INFANTS OR ADULTS
EXPOSED TO 100% OXYG EN MAY SUFFER DELAYED RETINAL DAMAGE, WHICH
CAN PROGRESS TO RETINAL DETACHMENT & BLINDNESS.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION
IF NOT BREATHING. KEEP VICTIM WARM & AT REST. OBTAIN MEDICAL
ATTENTION IN ALL CASES. PHYSICIAN NOTE: SUPPORTIVE TREATMENT SHOULD
INCLUDE IM MEDIATE SEDATION/ANTI-CONVULSIVE THERAPY/REST. ALL
INDIVIDUALS EXPOSED FOR LONG PERIODS TO OXYGEN AT HIGH PRESSURE &
ALL WHO EXHIBIT OVERT OXYGEN TOXICITY SHOULD HAVE OPHTHALMOLOGIC
EXAMINATIONS.

Fire Fighting

Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE. WATER
IS THE PREFERRED EXTINGUISHING MEDIA FOR CLOTHING FIRES.
Fire Fighting Procedures:EVACUATE ALL PERSONNEL FROM DANGER AREA. COOL
CONTAINERS W/WATER SPRAY FROM MAXIMUM DISTANCE UNTIL COOL, THEN
MOVE CONTAINERS AWAY FROM FIRE AREA SAFELY.
Unusual Fire/Explosion Hazard:CONTACT W/FLAMMABLE MATERIAL MAY CAUSE
FIRE/EXPLOSION. CONTAINER MAY RUPTURE DUE TO HEAT OF FIRE OR
REVERSE FLOW INTO CYLINDER. COMBUSTIBLE/HIGH PRESSURE GAS.

Accidental Release

Spill Release Procedures:SHUT OFF LEAK IF W/OUT RISK. VENTILATE AREA OF
LEAK OR MOVE LEAKING CONTAINER TO WELL-VENTILATED AREA. REMOVE ALL
FLAMMABLE MATERIALS FROM VICINITY. IF THERE IS A LEAK, CLOSE
CYLINDER VALVE/BLOW DOWN SYSTEM BY VENTING TO SAFE PLACE/REPAIR
THE LEAK.

Handling

Handling and Storage Precautions:NEVER LUBRICATE OXYGEN
VALVES/REGULATORS/ETC. W/ANY COMBUSTIBLE SUBSTANCE. DON'T USE
OXYGEN JET TO CLEAN, INCREASES DANGER OF ENGULFING FIRE.
Other Precautions:USE ONLY W/EQUIPMENT CONDITIONED FOR OXYGEN SERVICE.
OXYGEN MUST NEVER BE PERMITTED TO STRIKE AN OILY SURFACE/GREASY
CLOTHES/OTHER COMBUSTIBLE MATERIAL. ISOLATE FROM IGNITION SOURCES.
USE CHECK VALVE IN ANY LINE OF PIPING FROM CYLINDER.

Exposure Controls

Respiratory Protection:AS REQUIRED
Ventilation:MECHANICAL (GENERAL): ACCEPTABLE.
Protective Gloves:PREFERRED FOR CYLINDER HANDLING
Eye Protection:AS REQUIRED
Other Protective Equipment:SAFETY SHOWER & METATARSAL SHOES FOR
CYLINDER HANDLING
Supplemental Safety and Health
WHEN 2 OR MORE GASES OR LIQUEFIED GASES ARE MIXED, THEIR HAZARDOUS
PROPERTIES MAY COMBINE TO CREATE ADDITIONAL UNEXPECTD HAZARDS.
READ/UNDERSTAND LABEL PRECAUTION/SAFETY INFORMATION BEFORE
PRODUCING M IXTURE. MOST CONTAINERS ARE PROVIDED W/PRESSURE RELIEF
DEVICE DESIGNED TO VENT CONTENTS WHEN EXPOSED TO HIGH TEMP.

Chemical Properties

Boiling Pt:B.P. Text:-297.4F
Melt/Freeze Pt:M.P/F.P Text:-361.1F
Vapor Pres:GAS
Vapor Density:1.105
Spec Gravity:GAS
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS, COMBUSTIBLE MATERIALS, ASPHALT, FLAMMABLE MATERIALS,
ESPECIALLY OILS & GREASES
Stability Condition to Avoid:TEMPERATURE >125F, FLAMES, ELECTRIC
SPARKS, PHYSICAL DAMAGE, OVER-HEATING

Disposal

Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE, IN AN OPEN,
OUTDOORS AREA IN ACCORDANCE W/LOCAL, STATE, & FEDERAL REGULATIONS.
COMBUSTIBLE, HIGH PRESSURE GAS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.